Air Conditioning
|
Parts Inspected
|
Service Provided
|
Value of Service
|
|
Air Filter
|
Inspect and replace if dirty
|
A restricted air filter will cause improper air flow, waste energy, and can shorten the life of your compressor
|
|
Condenser Coil
|
Clean coil and inspect fins
|
A dirty condenser coil raises refrigerant pressure, increasing energy costs
|
|
Blower Assembly
|
Inspect and clean blower assembly
|
A dirty blower assembly reduces air flow requiring longer operating time, increasing energy costs and reducing comfort
|
|
Refrigerant Charge
|
Checked by super-heat/sub-cooling gauges
|
Improper refrigerant levels can damage compressor and increase energy costs. Also, improper refrigerant levels can mean that you have a leak in your system.
|
|
Evaporator Coil
|
Inspect and clean evaporator coil
|
A restricted air filter will cause improper air flow, reduced air quality, waste energy, and can shorten the life of your compressor.
|
|
Thermostat
|
Calibration and operation
|
A thermostat not operating properly can reduce comfort and cause unit to run inefficiently.
|
|
Condenser Motor
|
Inspect and oil/lubricate if necessary
|
Properly operating motors keep unit running efficiently
|
|
Controls and Safety Devices
|
Inspect and test
|
Controls and saftey devices not operating properly can increase operating costs and cause other components to fail.
|
|
Condensate Drain
|
Inspect and unclog if necessary
|
A clogged condensate drain can overflow from drain pan causing water damage.
|
|
Relays and Contactors
|
Inspect and test
|
Worn contactors and relays can lead to motor or compressor failure.
|
|
Capacitors
|
Inspect & Test
|
A capacitor that is not functioning properly can cause a motor to fail.
|
|
Fan Blade
|
Inspect
|
A damaged fan blade can affect operation of condenser.
|
|
Disconnect and wiring
|
Inspect and tighten connections, check voltage with gauges
|
A worn disconnect can blow fuses and loose wiring connections can lead to motor or compressor failure.
|
|
Belts and pulleys
|
Inspect and adjust if necessary
|
Loose belts and worn pulleys reduce air flow, increase operating costs.
|
|
Coil Air Temperatures
|
Measure Air Temperatures Across Evaporator Coil
|
Measure temperatures to verify proper operation.
|
|
Defrost Timer (Heat Pumps)
|
Inspect
|
A defrost timer that is not working properly can cause a loss of heat and can shorten the life of the compressor.
|
|
Reversing Valve (Heat Pumps)
|
Inspect Operation
|
A reversing valve that is not working properly increases energy costs and can cause compressor failure.
|
|
Heating
|
Parts Inspected
|
Service Provided
|
Value of Service
|
|
Air Filter
|
Inspect and replace if dirty
|
A restricted air filter will cause improper air flow, waste energy, and can shorten the life of your compressor
|
|
Gas Burners
|
Inspect and clean
|
A dirty burner can cause poor combustion and reduce efficiency
|
|
Pilot Assembly
|
Clean and adjust if necessary
|
A weak or dirty pilot can result in unreliable operation and cause unit to shut down
|
|
Thermocouple
|
Inspect
|
A defective thermocouple will cause the furnace to shut down
|
|
Flame Sensor
|
Inspect and clean
|
A dirty flame sensor can result in unreliable operation
|
|
Blower Assembly
|
Inspect and clean blower assembly
|
A dirty blower assembly reduces air flow requiring longer operating time, increasing energy costs and reducing comfort
|
|
Heat Exchanger
|
Inspect for cracks and deterioration
|
A cracked heat exchanger can result in the risk of toxic fumes being emitted
|
|
Condensate Drain
|
Inspect and unclog if necessary
|
A clogged condensate drain can overflow from drain pan causing water damage
|
|
Flue Pipe
|
Inspect
|
A rusted flue pipe can result in carbon monoxide leaks
|
|
Motor
|
Inspect and oil/lubricate if necessary
|
Properly operating motors keep unit running efficiently
|
|
Fan Switch
|
Inspect and adjust if necessary
|
A fan switch that is not properly adjusted can increase energy costs
|
|
Controls and Safety Devices
|
Inspect and test
|
Controls and safety devices not operating properly can increase operating costs and cause other components to fail
|
|
Combustion Air
|
Inspect openings to mechanical equipment room
|
Blocked or restricted combustion air openings will affect operation of unit and can be dangerous
|
|
Panels
|
Inspect and secure
|
Loose panels will affect operation of unit and can be dangerous
|
|
Thermostat
|
Calibration and operation
|
A thermostat not operating properly can reduce comfort and cause unit to run inefficiently
|
|
Gas Line and Gas Valves
|
Inspect
|
A gas line with leaks is dangerous
|
|
Auxillary Heat Strips (Heat Pumps)
|
Inspect
|
Heat strips not operating properly can result in heat loss
|